Single vs. Double Dartos Interposition Flaps in Preventing Urethrocutaneous Fistula after Tubularized Incised Plate Urethroplasty in Primary Distal Hypospadias: A Prospective Randomized Study

Yükleniyor...
Küçük Resim

Tarih

2009

Dergi Başlığı

Dergi ISSN

Cilt Başlığı

Yayıncı

Karger

Erişim Hakkı

info:eu-repo/semantics/closedAccess

Özet

Introduction: This prospective study was designed to compare symmetrical overlapping double flaps with a single dartos flap in regard to fistula formation as an adjunct to tubularized incised plate urethroplasty (TIPU). Patients and Methods: 77 consecutive children with primary coronal or subcoronal hypospadias were randomized into 2 groups. A single layer dartos flap was used to cover the anastomotic site in the first group (37 patients). A wider dorsal dartos flap bisectioned in the midline was utilized in the second group of 40 patients. The complication rates were compared. Results: There was no difference between the 2 groups in terms of age, and meatal location. Postoperative median follow-up was 34 months. Urethrocutaneous fistula occurred in 3 patients (8.1%) of the monolayer group. No fistula developed in the second group with double flaps. Conclusions: The current study proposes that the use of double dorsal flaps, although statistically not significant, better prevents fistula formation compared to monolayer dartos flaps following TIPU operation. Copyright (C) 2009 S. Karger AG, Basel

Açıklama

WOS: 000270779400021
PubMed: 19829040

Anahtar Kelimeler

Hypospadias, Urethra, Urosurgical procedures, Urinary fistula, Surgical flaps

Kaynak

Urologia Internationalis

WoS Q Değeri

Q4

Scopus Q Değeri

Q2

Cilt

83

Sayı

3