Development and Validation of Gas Chromatography - Mass Spectrometry Method for Determination of Aldrin and Dieldrin in Serum

dc.contributor.authorKaya, Betül İşiner
dc.contributor.authorGürler, Mukaddes
dc.date.accessioned2023-04-10T20:31:04Z
dc.date.available2023-04-10T20:31:04Z
dc.date.issued2022
dc.departmentRektörlük, Rektörlüğe Bağlı Birimler, Düzce Üniversitesi Dergilerien_US
dc.description.abstractAim: Exposure to many banned pesticides continues all over the world and in our country due to the long half-lives of pesticides. Therefore, the purpose of the study was to obtain a rapid, simple, and convenient method for the simultaneous determination of aldrin and dieldrin. Material and Methods: Method improving and validation assessment are the most important elements for establishing reference techniques and reliable analysis results. In order to analyze analytes, validation of the analytical method is carried out by checking the parameters of specificity, recovery, precision, linearity, the limit of detection (LOD), and the limit of quantification (LOQ). Results: In our study, an easily applicable, so rapid, effective, and safe GC-MS method was created for the determination of aldrin and dieldrin in serum. In the developed method, 4,4'-Dichlorobenzophenone (4,4-DBP) was used as the internal standard. Aldrin and dieldrin were analyzed in serum in a very short time of 4 minutes. Linear correlation coefficients (R2 ? 0.99) of the linear calibration curves between a range of 1-250 ng/mL of analytes in serum were established. The limit of detection for aldrin and dieldrin were 0.28 and 0.29 ng/mL, respectively. More than 80% recovery of aldrin and dieldrin were obtained at high concentrations, and consistent relative standard deviation (RSD ? 6.03%) values were found for both pesticides. Conclusion: This new method can reliably and quickly be used in routine analysis. The study showed that exposure to aldrin and dieldrin can be detected and monitored in such a short time as four minutes.en_US
dc.identifier.doi10.33631/sabd.1103985
dc.identifier.endpage198en_US
dc.identifier.issn2792-0542
dc.identifier.issue2en_US
dc.identifier.startpage194en_US
dc.identifier.trdizinid516647en_US
dc.identifier.urihttp://doi.org/10.33631/sabd.1103985
dc.identifier.urihttps://search.trdizin.gov.tr/yayin/detay/516647
dc.identifier.urihttps://hdl.handle.net/20.500.12684/12054
dc.identifier.volume12en_US
dc.indekslendigikaynakTR-Dizinen_US
dc.language.isoenen_US
dc.relation.ispartofSağlık Bilimlerinde Değer (Online)
dc.relation.publicationcategoryMakale - Ulusal Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectdieldrinen_US
dc.subjectAldrin dieldrinen_US
dc.titleDevelopment and Validation of Gas Chromatography - Mass Spectrometry Method for Determination of Aldrin and Dieldrin in Serumen_US
dc.typeArticleen_US

Dosyalar

Orijinal paket
Listeleniyor 1 - 1 / 1
Yükleniyor...
Küçük Resim
İsim:
12054.pdf
Boyut:
787.29 KB
Biçim:
Adobe Portable Document Format
Açıklama:
Tam Metin / Full Text