Is Saturation Biopsy Still a Viable Alternative to Fusion Biopsy in the Era of Multiparametric MRI? A Comparative Analysis in Patients With Prior Negative Biopsy

dc.contributor.authorTaskiran, Arda Taskin
dc.contributor.authorSenoglu, Yusuf
dc.date.accessioned2026-07-01T11:40:15Z
dc.date.available2026-07-01T11:40:15Z
dc.date.issued2026
dc.departmentDüzce Üniversitesi
dc.description.abstractBackground: We aimed to compare the diagnostic accuracy of transrectal ultrasound (TRUS)-guided saturation biopsy (SB) and multiparametric MRI (mpMRI)-TRUS fusion-guided combined biopsy (CB) in patients with prior negative prostate biopsies. Methods: We retrospectively analyzed data from 160 patients who underwent transrectal prostate biopsy between January 2014 and March 2021. All had at least one prior negative biopsy. 80 patients underwent SB with a 20-core TRUS-guided approach. The remaining 80 patients, with mpMRI-detected PIRADS >= 3 lesions, underwent CB including 12-core systematic plus 2-4 targeted cores per lesion. Prostate cancer and clinically significant prostate cancer (csPCa) detection rates, and clinical parameters were compared between groups. Results: The groups had no statistically significant differences in baseline characteristics. The PCa detection rate was 20% in the CB group and 16.3% in the SB group (p = 0.682). csPCa detection rates were also similar: 11.3% in the CB cohort and 7.5% in the SB cohort (p = 0.589). Notably, the CB subgroup with PI-RADS >= 4 lesions had a significantly higher csPCa detection rate (28.6%) than SB group (7.5%) (p = 0.016). Patients diagnosed with PCa had significantly lower free PSA and free/total PSA ratios (p < 0.05). Complication rates were low and similar in both groups. Conclusions: CB demonstrates the highest diagnostic yield for detecting csPCa, particularly in patients with PI-RADS >= 4 lesions. However, in resource-limited settings lacking mpMRI, systematic saturation biopsy remains a viable, safe, and effective alternative. PSA derivatives may serve as complementary tools to refine biopsy decisions.
dc.identifier.doi10.1002/pros.70169
dc.identifier.endpage996
dc.identifier.issn0270-4137
dc.identifier.issn1097-0045
dc.identifier.issue9
dc.identifier.orcid0000-0003-4556-3475
dc.identifier.pmid41911500
dc.identifier.scopus2-s2.0-105034298861
dc.identifier.scopusqualityQ1
dc.identifier.startpage990
dc.identifier.urihttps://doi.org/10.1002/pros.70169
dc.identifier.urihttps://hdl.handle.net/20.500.12684/23721
dc.identifier.volume86
dc.identifier.wosWOS:001728622000001
dc.identifier.wosqualityQ2
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakScopus
dc.indekslendigikaynakPubMed
dc.language.isoen
dc.publisherWiley
dc.relation.ispartofProstate
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı
dc.rightsinfo:eu-repo/semantics/openAccess
dc.snmzKA_WOS_20260623
dc.subject[Keyword Not Available]
dc.titleIs Saturation Biopsy Still a Viable Alternative to Fusion Biopsy in the Era of Multiparametric MRI? A Comparative Analysis in Patients With Prior Negative Biopsy
dc.typeArticle

Dosyalar