Application of Deep Cryogenic Treatment to Uncoated Tungsten Carbide Inserts in the Turning of AISI 304 Stainless Steel
Yükleniyor...
Dosyalar
Tarih
2016
Dergi Başlığı
Dergi ISSN
Cilt Başlığı
Yayıncı
Springer
Erişim Hakkı
info:eu-repo/semantics/closedAccess
Özet
This study investigated the effects of deep cryogenic treatment (DCT) on the wear performance of uncoated tungsten carbide inserts. AISI 304 austenitic stainless steel, widely used in industry, was selected as the workpiece material. Cutting experiments showed that the amount of wear significantly increased with increasing cutting speed. In addition, it was found that DCT contributed to the wear resistance of the turning inserts. The treated turning inserts were less worn by 48 and 38 pct in terms of crater wear and notch wear, respectively, whereas they exhibited up to 18 pct superior wear performance in terms of flank wear. This was attributed to the precipitation of new and finer eta-carbides and their homogeneous distribution in the microstructure of the tungsten carbide material after deep cryogenic treatment. Analyses via image processing, hardness measurements, and SEM observations confirmed these findings.
Açıklama
Ozbek, Orhan/0000-0002-7388-0542; OZBEK, Onur/0000-0002-8372-3487; Altan Ozbek, Nursel/0000-0003-3241-9423
WOS: 000387856000065
WOS: 000387856000065
Anahtar Kelimeler
Kaynak
Metallurgical And Materials Transactions A-Physical Metallurgy And Materials Science
WoS Q Değeri
Q1
Scopus Q Değeri
Q1
Cilt
47A
Sayı
12