Investigation of the effect of exhaust particles on ocular blood flow in highway toll collectors using color Doppler ultrasonography
dc.contributor.author | Erdoğmuş, Beşir | |
dc.contributor.author | Yazıcı, Burhan | |
dc.contributor.author | Önder, Halil İbrahim | |
dc.contributor.author | Bilgin, Cahit | |
dc.contributor.author | Tugay, Ali | |
dc.contributor.author | Büyükkaya, Ramazan | |
dc.date.accessioned | 2020-04-30T23:18:41Z | |
dc.date.available | 2020-04-30T23:18:41Z | |
dc.date.issued | 2007 | |
dc.department | DÜ, Tıp Fakültesi, Dahili Tıp Bilimleri Bölümü | en_US |
dc.description | BILGIN, CAHIT/0000-0003-2213-5881 | en_US |
dc.description | WOS: 000245792000018 | en_US |
dc.description | PubMed: 17354145 | en_US |
dc.description.abstract | Purpose: To investigate the effect of exhaust particles on orbital blood flow velocity of the ophthalmic artery, central retinal artery, and posterior ciliary artery by color Doppler ultrasonography in highway toll collectors. Material and Methods: Color Doppler imaging was used to measure the peak-systolic and end-diastolic flow velocities and resistivity indices of the ophthalmic artery, central retinal artery, and posterior ciliary artery in 20 toll collectors and 20 controls. Results: Both the peak-systolic and the end-diastolic flow velocities were decreased in the ophthalmic artery, central retinal artery, and posterior ciliary artery, and the resistivity index was increased in the central retinal artery in toll collectors when compared with control groups. Results were considered statistically significant if P < 0.05. Conclusion: It was determined that the effect of exhaust particles reduced ocular blood flow velocity in toll collectors as measured by color duplex Doppler ultrasonography. | en_US |
dc.identifier.doi | 10.1080/02841850601129023 | en_US |
dc.identifier.endpage | 227 | en_US |
dc.identifier.issn | 0284-1851 | |
dc.identifier.issue | 2 | en_US |
dc.identifier.scopusquality | Q3 | en_US |
dc.identifier.startpage | 223 | en_US |
dc.identifier.uri | https://doi.org/10.1080/02841850601129023 | |
dc.identifier.uri | https://hdl.handle.net/20.500.12684/3474 | |
dc.identifier.volume | 48 | en_US |
dc.identifier.wos | WOS:000245792000018 | en_US |
dc.identifier.wosquality | Q4 | en_US |
dc.indekslendigikaynak | Web of Science | en_US |
dc.indekslendigikaynak | PubMed | en_US |
dc.indekslendigikaynak | Scopus | en_US |
dc.language.iso | en | en_US |
dc.publisher | Taylor & Francis Ltd | en_US |
dc.relation.ispartof | Acta Radiologica | en_US |
dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | en_US |
dc.rights | info:eu-repo/semantics/closedAccess | en_US |
dc.subject | air pollution | en_US |
dc.subject | color Doppler ultrasonography | en_US |
dc.subject | exhaust particles | en_US |
dc.subject | ocular blood flow | en_US |
dc.subject | toll collector | en_US |
dc.title | Investigation of the effect of exhaust particles on ocular blood flow in highway toll collectors using color Doppler ultrasonography | en_US |
dc.type | Article | en_US |
Dosyalar
Orijinal paket
1 - 1 / 1
Küçük Resim Yok
- İsim:
- 3474.pdf
- Boyut:
- 245.82 KB
- Biçim:
- Adobe Portable Document Format
- Açıklama:
- Tam Metin / Full Text