Investigation of Frequency Dependent Electrical and Dielectric Properties of Maple Wood (Acer Trautvetteri Medw.) with Different Surface Treatments

Küçük Resim Yok

Tarih

2026

Dergi Başlığı

Dergi ISSN

Cilt Başlığı

Yayıncı

Lukasiewicz Research Network, Poznan Inst Technology

Erişim Hakkı

info:eu-repo/semantics/openAccess

Özet

In this study, the electrical and dielectric properties of maple wood (Acer trautvetteri Medw.) were comprehensively investigated under three different surface conditions: untreated control (CW), two-week water immersion (SW), and double varnish (VW), as well as a function of frequency. For the accuracy of electrical analysis, all test samples were evaluated in a dry state and comparative analysis was performed between surface treatment groups. In the experimental analyses in the frequency range from 100 Hz to 1 MHz, reel/imaginary part of dielectric permittivity (epsilon ' and epsilon ''), dielectric loss factor (tans), alternating current electrical conductivity (sigma ac), specific heat capacity (C), conductivity-dependent free energy component (G/omega), and real (Z ') and imaginary (Z '') impedance components were comprehensively evaluated. According to the test results, the SW test samples, with their high (epsilon ') and (epsilon '') values, were found to provide significant ionic and dipolar contributions. However, due to their high (tans) and (sigma ac) values, their energy storage capacity is limited, and their conductivity potential is high. The VW test samples, with their low (epsilon '') and (tans) values, exhibit strong insulating properties, making them suitable for high-frequency capacitive applications. The CW test samples, in contrast, exhibit a balanced conductivity-insulation profile with moderate dielectric response. Impedance analyses (Z ', Z '') revealed that the low-resistance ion transport mechanism dominates in the SW test samples, while the surface coating creates a high-resistance barrier, thus limiting charge transport in the VW test samples. The (G/omega) results indicate high energy dissipation in the SW test samples over a wide frequency range, while the VW test samples exhibit stable storage behavior with low energy loss. According to the test results, maple wood, depending on the surface treatment, has potential for use in sensor technologies (SW), radiofrequency isolating components (VW), and general structural dielectric applications (CW), and allows for targeted performance engineering through material modification.

Açıklama

Anahtar Kelimeler

Maple Wood, Dielectric Properties, Frequency-Dependent Behavior, Complex Impedance, Electric Modulus

Kaynak

Drewno

WoS Q Değeri

Q3

Scopus Q Değeri

Q3

Cilt

69

Sayı

217

Künye