Effect of a 50-Hz Sinusoidal Electromagnetic Field on the Integrity of Experimental Colonic Anastomoses Covered with Fibrin Glue

dc.contributor.authorGirgin, Sadullah
dc.contributor.authorÖztürk, Hayrettin
dc.contributor.authorGedik, Ercan
dc.contributor.authorAkpolat, Veysi
dc.contributor.authorKale, Ebru
dc.contributor.authorÖztürk, Hülya
dc.date.accessioned2020-05-01T09:11:35Z
dc.date.available2020-05-01T09:11:35Z
dc.date.issued2009
dc.departmentDÜ, Tıp Fakültesi, Cerrahi Tıp Bilimleri Bölümüen_US
dc.descriptionKale, Ebru/0000-0002-1194-6649; H, Ozturk/0000-0001-5608-5742; Akpolat, Veysi/0000-0002-2435-7800en_US
dc.descriptionWOS: 000270038600002en_US
dc.description.abstractBackground. Low-frequency magnetic fields have been shown to affect biological processes. In this article the effects of 50-Hz sinusoidal magnetic field (MF) stimulation and application of fibrin glue on the healing of experimental colonic anastomoses were investigated. Material and Methods. Twenty-eight rats were divided into four groups. Group 1 underwent 2-cm left colonic resection and primary anastomosis. Group 2 underwent normal resection anastomosis and the area was covered with fibrin glue. Group 3 underwent normal resection anastomosis and the rats were exposed to a 50-Hz sinusoidal MF. Group 4 underwent normal resection anastomosis, the anastomosis area was covered with fibrin glue, and the rats were exposed to a 50-Hz sinusoidal MF. Investigations included bursting pressure measurement, hydroxyproline content, and histopathological changes. Results. Tissue hydroxyproline levels and anastomotic bursting pressures of groups 2, 3, and 4 were significantly higher than in group 1. Collagen deposition and fibroblast infiltration in groups 2, 3, and 4 had higher scores than in group 1. Furthermore, these results were significantly higher in group 4 rats than in the other groups. Histopathological examination of the anastomosis revealed significantly better healing patterns for group 4 than for groups 1, 2, and 3. Conclusions. A50-Hz sinusoidal MF stimulation and application of fibrin glue provided a significant gain in anastomotic healing in the large intestine. A combination of a 50-Hz sinusoidal MF and fibrin glue has significantly favorable effects on healing of experimental colon anastomosis (Adv Clin Exp Med 2009, 18, 1, 13-18).en_US
dc.identifier.endpage18en_US
dc.identifier.issn1899-5276
dc.identifier.issue1en_US
dc.identifier.scopusqualityQ1en_US
dc.identifier.startpage13en_US
dc.identifier.urihttps://hdl.handle.net/20.500.12684/5673
dc.identifier.volume18en_US
dc.identifier.wosWOS:000270038600002en_US
dc.identifier.wosqualityQ4en_US
dc.indekslendigikaynakWeb of Scienceen_US
dc.indekslendigikaynakScopusen_US
dc.language.isoenen_US
dc.publisherWroclaw Medical Univen_US
dc.relation.ispartofAdvances In Clinical And Experimental Medicineen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectcolonic anastomosisen_US
dc.subject50-Hz sinusoidal magnetic fielden_US
dc.subjectfibrin glueen_US
dc.titleEffect of a 50-Hz Sinusoidal Electromagnetic Field on the Integrity of Experimental Colonic Anastomoses Covered with Fibrin Glueen_US
dc.typeArticleen_US

Dosyalar

Orijinal paket
Listeleniyor 1 - 1 / 1
Küçük Resim Yok
İsim:
5673.pdf
Boyut:
72.91 KB
Biçim:
Adobe Portable Document Format
Açıklama:
Tam Metin / Full Text