Aging and cardiac implantable electronic device complications: is the procedure safe in older patients?

dc.authoridAktan, Adem/0000-0003-0505-9784en_US
dc.authoridArslan, Bayram/0000-0003-2984-9094en_US
dc.authoridGüzel, Tuncay/0000-0001-8470-1928en_US
dc.authoridAYDIN, SAADET/0000-0003-0817-1026en_US
dc.authoridGunlu, Serhat/0000-0001-6985-6112en_US
dc.authoridTatli, Ismail/0000-0002-9800-2105en_US
dc.authoridKILIC, RAIF/0000-0002-8338-4948en_US
dc.authorscopusid57217383386en_US
dc.authorscopusid56783879500en_US
dc.authorscopusid57697525300en_US
dc.authorscopusid57756126300en_US
dc.authorscopusid57194141868en_US
dc.authorscopusid58286243100en_US
dc.authorscopusid58541827300en_US
dc.authorwosidAktan, Adem/GMX-2603-2022en_US
dc.authorwosidArslan, Bayram/KFQ-1082-2024en_US
dc.authorwosidGüzel, Tuncay/AAC-9120-2022en_US
dc.contributor.authorGuzel, Tuncay
dc.contributor.authorAktan, Adem
dc.contributor.authorKilic, Raif
dc.contributor.authorGunlu, Serhat
dc.contributor.authorArslan, Bayram
dc.contributor.authorArpa, Abdulkadir
dc.contributor.authorGuzel, Hamdullah
dc.date.accessioned2024-08-23T16:04:58Z
dc.date.available2024-08-23T16:04:58Z
dc.date.issued2023en_US
dc.departmentDüzce Üniversitesien_US
dc.description.abstractBackgroundIn this study, we investigated whether there is a higher incidence of cardiac implantable electronic devices (CIED) procedures related complications in older (& GE; 75 years) than in younger (< 75 years) patients.MethodsThis retrospective cohort study enrolled patients who had undergone CIED procedures (de novo implantation, system upgrade, generator substitution, pocket revision or lead replacement) at two heart centers in Turkey between January 2011 and May 2023. The primary composite endpoint included clinically significant hematoma (CSH), pericardial effusion or tamponade, pneumothorax, and infection related to the device system. Secondary outcomes included each component of the composite end point.ResultsThe overall sample included 1923 patients (1419 < 75 years and 504 aged & GE; 75 years). There was no difference between the groups in terms of cumulative events defined as primary outcome (3.5% vs. 4.4%, p = 0.393). Infection related to device system was significantly higher in the & GE; 75 age group (1.8% vs. 3.4%, p = 0.034). There was no significant difference between the groups in terms of clinically significant hematoma and pneumothorax (0.7% vs. 0.4%, p = 0.451, 1.4% vs. 1.0%, p = 0.477, respectively). In multivariate model analysis, no association was found between age & GE; 75 years and infection related to the device system.ConclusionInfection rates were relatively higher in the patient group aged & GE; 75 years. This patient group should be evaluated more carefully in terms of infection development before and after the procedure.en_US
dc.identifier.doi10.1007/s40520-023-02524-6
dc.identifier.endpage2452en_US
dc.identifier.issn1594-0667
dc.identifier.issn1720-8319
dc.identifier.issue11en_US
dc.identifier.pmid37599325en_US
dc.identifier.scopus2-s2.0-85168335389en_US
dc.identifier.scopusqualityQ2en_US
dc.identifier.startpage2445en_US
dc.identifier.urihttps://doi.org/10.1007/s40520-023-02524-6
dc.identifier.urihttps://hdl.handle.net/20.500.12684/14438
dc.identifier.volume35en_US
dc.identifier.wosWOS:001051147500001en_US
dc.identifier.wosqualityQ2en_US
dc.indekslendigikaynakWeb of Scienceen_US
dc.indekslendigikaynakScopusen_US
dc.indekslendigikaynakPubMeden_US
dc.language.isoenen_US
dc.publisherSpringeren_US
dc.relation.ispartofAging Clinical and Experimental Researchen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectPacemakeren_US
dc.subjectCardiovascular implantable electronic devicesen_US
dc.subjectComplicationen_US
dc.subjectElderlyen_US
dc.subjectPopulation-Based-Cohorten_US
dc.subjectCardioverter-Defibrillatoren_US
dc.subjectResynchronization Therapyen_US
dc.subjectEuropean-Societyen_US
dc.subjectPocket Hematomaen_US
dc.subjectCardiology Escen_US
dc.subjectTask-Forceen_US
dc.subjectInfectionen_US
dc.subjectRisken_US
dc.subjectPacemakersen_US
dc.titleAging and cardiac implantable electronic device complications: is the procedure safe in older patients?en_US
dc.typeArticleen_US

Dosyalar