Kirschner wire configuration and fixation stability in pediatric supracondylar humerus fractures: a finite element analysis

dc.contributor.authorAkar, Bedrettin
dc.contributor.authorIyibilgin, Osman
dc.contributor.authorOzturkmen, Yusuf
dc.contributor.authorSoydas, Suleyman
dc.contributor.authorYucel, Mucahid Osman
dc.date.accessioned2026-07-01T11:39:38Z
dc.date.available2026-07-01T11:39:38Z
dc.date.issued2025
dc.departmentDüzce Üniversitesi
dc.description.abstractBackground Pediatric supracondylar humerus fractures are among the most common elbow injuries in children and require stable fixation to prevent complications. Kirschner (K) wire osteosynthesis is a widely used technique; however, the optimal wire configuration remains a subject of debate. Objective This study aims to investigate the effects of three different K-wire configurations (crossed, medial-parallel, and lateral-parallel) on the fixation stability of pediatric supracondylar humerus fractures using finite element analysis (FEA). Methods A three-dimensional finite element model of a pediatric humerus with a supracondylar fracture was constructed. Each of the three K-wire configurations was virtually applied to the model.To replicate physiological conditions, force (Z-axis) and moment (X-and Y-axes) components were applied under various loading scenarios, both individually and in combination. Mechanical parameters, including displacement, stress distribution, and rigidity, were analyzed for each configuration. Results The crossed K-wire configuration demonstrated superior structural stability compared to both medial-parallel and lateral-parallel configurations. It exhibited lower displacement values and more favorable stress distribution, particularly under rotational loading conditions, indicating higher mechanical resistance. Conclusion The findings suggest that the crossed K-wire configuration provides enhanced fixation stability and may be the most effective technique for the surgical treatment of pediatric supracondylar humerus fractures. Additionally, this study confirms the utility of finite element analysis as a robust and reliable method for evaluating the biomechanical performance of orthopedic fixation methods.
dc.identifier.doi10.1186/s13018-025-06437-0
dc.identifier.issn1749-799X
dc.identifier.issue1
dc.identifier.orcid0000-0002-3542-5805
dc.identifier.orcid0000-0001-7461-1777
dc.identifier.orcid0000-0002-1288-1920
dc.identifier.pmid41258060
dc.identifier.scopus2-s2.0-105022233214
dc.identifier.scopusqualityN/A
dc.identifier.urihttps://doi.org/10.1186/s13018-025-06437-0
dc.identifier.urihttps://hdl.handle.net/20.500.12684/23387
dc.identifier.volume20
dc.identifier.wosWOS:001619175500006
dc.identifier.wosqualityQ1
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakScopus
dc.indekslendigikaynakPubMed
dc.language.isoen
dc.publisherBmc
dc.relation.ispartofJournal of Orthopaedic Surgery and Research
dc.relation.publicationcategoryDiğer
dc.rightsinfo:eu-repo/semantics/openAccess
dc.snmzKA_WOS_20260623
dc.subjectSupracondylar Humerus Fracture
dc.subjectKirschner Wire
dc.subjectFinite Element Analysis
dc.subjectPediatric Orthopedics
dc.subjectFixation Stability
dc.subjectOsteosynthesis
dc.titleKirschner wire configuration and fixation stability in pediatric supracondylar humerus fractures: a finite element analysis
dc.typeLetter