Incidence and predictors of subclavian vein obstruction following biventricular device implantation

dc.contributor.authorBulur, Serkan
dc.contributor.authorVural, Ahmet
dc.contributor.authorYazıcı, Mehmet
dc.contributor.authorErtaş, Gökhan
dc.contributor.authorÖzhan, Hakan
dc.contributor.authorUral, Dilek
dc.date.accessioned2020-04-30T23:18:28Z
dc.date.available2020-04-30T23:18:28Z
dc.date.issued2010
dc.departmentDÜ, Tıp Fakültesi, Dahili Tıp Bilimleri Bölümüen_US
dc.descriptionWOS: 000284960000008en_US
dc.descriptionPubMed: 20890650en_US
dc.description.abstractThe data about the incidence of subclavian venous (SCV) obstruction or thrombosis after biventricular device implantation is limited. Therefore, we aimed to assess the incidence and predictors of venous obstruction after biventricular device implantation with or without a defibrillator in patients with left ventricular systolic dysfunction and cardiac dyssynchrony. Eighty-six patients who had undergone biventricular device implantation were included in the study. Subclavian vein was patent in 61% of all participants. Among the patients with subclavian obstruction (n = 33), 8 had mild obstruction, 15 had severe obstruction, and 10 had total occlusion. The presence of additional implantable cardioverter defibrillator (ICD) and the number of leads that were used were found to be significant covariates of obstruction in subclavian vein after biventricular device implantation (p = 0.004 and p = 0.01, respectively). Atrial fibrillation after biventricular pacemaker and ICD implantation was significantly related with total occlusion (r = 0.3, p = 0.005 and r = 0.24, p = 0.003, respectively). Patients who are candidates for biventricular device implantation are at increased risk for venous obstruction when compared with other pacemaker patients and this causes higher incidence of venous obstruction among these patients.en_US
dc.identifier.doi10.1007/s10840-010-9516-2en_US
dc.identifier.endpage202en_US
dc.identifier.issn1383-875X
dc.identifier.issue3en_US
dc.identifier.scopusqualityN/Aen_US
dc.identifier.startpage199en_US
dc.identifier.urihttps://doi.org/10.1007/s10840-010-9516-2
dc.identifier.urihttps://hdl.handle.net/20.500.12684/3335
dc.identifier.volume29en_US
dc.identifier.wosWOS:000284960000008en_US
dc.identifier.wosqualityQ3en_US
dc.indekslendigikaynakWeb of Scienceen_US
dc.indekslendigikaynakPubMeden_US
dc.indekslendigikaynakScopusen_US
dc.language.isoenen_US
dc.publisherSpringeren_US
dc.relation.ispartofJournal Of Interventional Cardiac Electrophysiologyen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectPacemakeren_US
dc.subjectBiventricularen_US
dc.subjectComplicationen_US
dc.subjectObstructionen_US
dc.titleIncidence and predictors of subclavian vein obstruction following biventricular device implantationen_US
dc.typeArticleen_US

Dosyalar

Orijinal paket
Listeleniyor 1 - 1 / 1
Küçük Resim Yok
İsim:
3335.pdf
Boyut:
107.79 KB
Biçim:
Adobe Portable Document Format
Açıklama:
Tam Metin / Full Text