Parametric optimization of an impingement jet solar air heater for active green heating in buildings using hybrid CRITIC-COPRAS approach

dc.authoridAlwetaishi, Mamdooh/0000-0001-5053-4324en_US
dc.authoridSaboor, Shaik/0000-0002-0490-4766en_US
dc.authorscopusid57204851425en_US
dc.authorscopusid57211771508en_US
dc.authorscopusid57202959651en_US
dc.authorscopusid57196825693en_US
dc.authorscopusid57190847465en_US
dc.authorscopusid57193789174en_US
dc.authorscopusid57197875592en_US
dc.authorwosidAlwetaishi, Mamdooh/M-1322-2016en_US
dc.authorwosidSaboor, Shaik/M-8170-2018en_US
dc.contributor.authorKumar, Raj
dc.contributor.authorKumar, Sushil
dc.contributor.authorAgbulut, Uemit
dc.contributor.authorGuerel, Ali Etem
dc.contributor.authorAlwetaishi, Mamdooh
dc.contributor.authorShaik, Saboor
dc.contributor.authorSaleel, C. Ahamed
dc.date.accessioned2024-08-23T16:04:43Z
dc.date.available2024-08-23T16:04:43Z
dc.date.issued2024en_US
dc.departmentDüzce Üniversitesien_US
dc.description.abstractThis work aimed to optimize the parameters of discrete multi-arc shaped ribs (DMASRs) in a solar air heating system (SAHS) through multi-criteria decision-making techniques. In the experiment, the roughness parameters of DMASRs were varied to find the best parameter combination for optimal SAHS performance. The relative rib height (Hr /H) was varied from 0.025 to 0.047 , and the relative rib pitch (Pr /H) was varied from 0.58 to 3.1. The results obtained for the Nusselt number and friction factor, which determine the performance of the SAHS system, depend on the geometrical parameters of the roughness. The parameters of DMASRs did not show any discernible trend. Hence, a multi-decision criteria approach that uses criteria importance through inter-criteria correlation (CRITIC) and complex proportional assessment (COPRAS) hybrid techniques was employed to determine the best parameter combination for optimal performance. The novel aspect of this study includes the use of a hybrid method (experimental and analytical) to optimize the performance of SAHS roughened with DMASRs hindrance promoters and predictions of outcomes using a hybrid CRITIC-COPRAS approach. The experimental and analytical examination through the use of the hybrid CRITIC-COPRAS approach is an essential component of this research that contributes to the optimization of the design parameters of such SAHS. The finding demonstrated that when Re = 19000, Pr/H = 1.7, and Hr/H = 0.047 were reached, the SAHS obtained an optimal thermohydraulic performance of 4.1.en_US
dc.description.sponsorshipDeanship of Scientific Research at King Khalid University [RGP 2/106/44]; Deanship of Scientific Research, Taif Universityen_US
dc.description.sponsorshipThe authors extend their appreciation to the Deanship of Scientific Research at King Khalid University for funding this work through large group Research Project under grant number RGP 2/106/44. The researchers would also like to acknowledge Deanship of Scientific Research, Taif University for funding this work.en_US
dc.identifier.doi10.1016/j.ijthermalsci.2023.108760
dc.identifier.issn1290-0729
dc.identifier.issn1778-4166
dc.identifier.scopus2-s2.0-85177977113en_US
dc.identifier.scopusqualityQ1en_US
dc.identifier.urihttps://doi.org/10.1016/j.ijthermalsci.2023.108760
dc.identifier.urihttps://hdl.handle.net/20.500.12684/14333
dc.identifier.volume197en_US
dc.identifier.wosWOS:001135150300001en_US
dc.identifier.wosqualityQ1en_US
dc.indekslendigikaynakWeb of Scienceen_US
dc.indekslendigikaynakScopusen_US
dc.language.isoenen_US
dc.publisherElsevier France-Editions Scientifiques Medicales Elsevieren_US
dc.relation.ispartofInternational Journal of Thermal Sciencesen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectGreen energyen_US
dc.subjectOptimizationen_US
dc.subjectCRITICen_US
dc.subjectCOPRASen_US
dc.subjectThermohydraulic performanceen_US
dc.subjectSolar air heating systemen_US
dc.subjectTransfer Enhancementen_US
dc.subjectPerformanceen_US
dc.subjectRoughnessen_US
dc.subjectCollectoren_US
dc.subjectPreferenceen_US
dc.subjectEntropyen_US
dc.subjectChannelen_US
dc.subjectEnergyen_US
dc.subjectFinsen_US
dc.titleParametric optimization of an impingement jet solar air heater for active green heating in buildings using hybrid CRITIC-COPRAS approachen_US
dc.typeArticleen_US

Dosyalar