Smartphone evaluation of postero-anterior chest x-rays: An inter-observer study

dc.contributor.authorBogan, Mustafa
dc.contributor.authorAltinsoy, Hasan Baki
dc.contributor.authorKaradag, Mehmet
dc.date.accessioned2021-12-01T18:48:20Z
dc.date.available2021-12-01T18:48:20Z
dc.date.issued2021
dc.department[Belirlenecek]en_US
dc.description.abstractBackground: Posterior-anterior chest x-ray (PA-CXR) is among the most commonly used imaging methods in the diagnosis both in the emergency departments (ED) and the other clinics. The aim of the present study was to evaluate the diagnostic reliability of PA-CXRs sent via a smartphone. Methods: This study was conducted as an inter-observer study. PA-CXRs were photographed with a smartphone and they were sent to two separate participants (emergency medicine specialists one with 4 years experience and another with 3) via the WhatsApp application. And the participants evaluated to these images on their mobile phone. Results: A poor concordance was determined in a ratio of 3/8 and good concordance was detected in a ratio of 3/8 between the two participants (p < 0.05). It was observed that only the mediastinum assessments could be an alternative to the gold standard (p < 0.01). Conclusion: We may conclude that the assessments done via a smartphone (photographing and sharing) may not be reliable. (C) 2020 Elsevier Inc. All rights reserved.en_US
dc.identifier.doi10.1016/j.ajem.2020.10.069
dc.identifier.endpage519en_US
dc.identifier.issn0735-6757
dc.identifier.issn1532-8171
dc.identifier.pmid33172746en_US
dc.identifier.scopus2-s2.0-85095784686en_US
dc.identifier.scopusqualityQ1en_US
dc.identifier.startpage515en_US
dc.identifier.urihttps://doi.org/10.1016/j.ajem.2020.10.069
dc.identifier.urihttps://hdl.handle.net/20.500.12684/10512
dc.identifier.volume46en_US
dc.identifier.wosWOS:000681308600015en_US
dc.identifier.wosqualityQ1en_US
dc.indekslendigikaynakWeb of Scienceen_US
dc.indekslendigikaynakPubMeden_US
dc.indekslendigikaynakScopusen_US
dc.language.isoenen_US
dc.publisherW B Saunders Co-Elsevier Incen_US
dc.relation.ispartofAmerican Journal Of Emergency Medicineen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectPosterior-anterior chest x-rayen_US
dc.subjectSmartphoneen_US
dc.subjectEmergency medicine specialistsen_US
dc.subjectEmergency-Departmenten_US
dc.subjectRadiologyen_US
dc.titleSmartphone evaluation of postero-anterior chest x-rays: An inter-observer studyen_US
dc.typeArticleen_US

Dosyalar

Orijinal paket
Listeleniyor 1 - 1 / 1
Küçük Resim Yok
İsim:
10512.pdf
Boyut:
221.29 KB
Biçim:
Adobe Portable Document Format
Açıklama:
Tam Metin / Full Text