Changes Of Optical Quality After Blinking
dc.contributor.author | Kılıç, Kuddusi | |
dc.contributor.author | Özkırış, Abdullah | |
dc.contributor.author | Erşekerci, Tülay Karacan | |
dc.contributor.author | İlhan, Nilüfer | |
dc.date.accessioned | 2024-12-28T20:19:11Z | |
dc.date.available | 2024-12-28T20:19:11Z | |
dc.date.issued | 2014 | |
dc.description.abstract | Purpose: To investigate changes in the optical quality of normal eyes associated with blinking.Methods: Between the ages of 18-46 (30.43 ± 9:54), ranging from 60 healthy subjects (28 male,32 female) were included in the study. Process postblink aberration measurements of the patientsafter 1 second (group 1) and 10 seconds (group 2) were made with Nidek-OPD SCAN.Results: Between group 1 and group 2, no significant difference was detected in the high-orderand spherical aberrations (p gt;0.05). Conclusion: A layer of tear film in normal subjects remained stable up to 10 seconds ensuresthat the optical quality is good | |
dc.description.abstract | Amaç: Normal gözlerde kırpma ile ilişkili optik kalitedeki değişiklikleri incelemek.Yöntem: Yaşları 18-46 arasında (30.43±9.54) değişen sağlıklı 60 olgu (28 erkek, 32 kadın)çalışma kapsamına alındı. Olguların aberasyon ölçümleri göz kırpma işleminden 1 saniye sonra(grup 1 ) ve 10 saniye sonra (grup 2) Nidek-OPD SCAN cihazı ile yapıldı. Bulgular: Grup 1 ile grup 2 arasında high-order ve sferik aberasyonlar açısından fark tespitedilmedi (p gt;0.05). Sonuç: Normal bireylerde göz yaşı film tabakası 10 saniyeye kadar stabil kalarak optik kaliteniniyi olmasını sağlar | |
dc.identifier.dergipark | DergiPark: 611411 | |
dc.identifier.endpage | 13 | |
dc.identifier.issn | 1307-671X | |
dc.identifier.issue | 2 | |
dc.identifier.startpage | 11 | |
dc.identifier.uri | https://dergipark.org.tr/tr/download/article-file/793731 | |
dc.identifier.uri | https://dergipark.org.tr/tr/pub/dtfd/issue/48290/611411 | |
dc.identifier.uri | https://hdl.handle.net/20.500.12684/15889 | |
dc.identifier.volume | 16 | |
dc.language.iso | tr | |
dc.publisher | Düzce Üniversitesi | |
dc.relation.ispartof | Düzce Tıp Fakültesi Dergisi | |
dc.relation.publicationcategory | Makale - Ulusal Hakemli Dergi | |
dc.rights | info:eu-repo/semantics/openAccess | |
dc.snmz | KA_20241228 | |
dc.subject | Blinking | |
dc.subject | optical quality | |
dc.subject | tear film | |
dc.subject | optical aberrations | |
dc.subject | Göz kırpma | |
dc.subject | optik kalite | |
dc.subject | göz yaşı filmi | |
dc.subject | optik aberasyon | |
dc.title | Changes Of Optical Quality After Blinking | |
dc.title.alternative | GÖZ KIRPMA SONRASI OPTİK KALİTEDEKİ DEĞİŞİKLİKLER | |
dc.type | Article |
Dosyalar
Orijinal paket
1 - 1 / 1