Correlation of bicarbonate values measured with direct enzymatic method and blood gas analysis devices

dc.contributor.authorMemişoğulları, Ramazan
dc.contributor.authorÖzcan, M. Engin
dc.contributor.authorCelbek, G.
dc.contributor.authorAnkaralı, H.
dc.contributor.authorAydın, Y.
dc.date.accessioned2020-04-30T13:32:16Z
dc.date.available2020-04-30T13:32:16Z
dc.date.issued2011
dc.departmentDÜ, Tıp Fakültesi, Temel Tıp Bilimleri Bölümüen_US
dc.description.abstractIntroduction: In this study, we investigated to whether there is a relationship between bicarbonate levels simultaneously measured with the mathematical calculation of blood gas analysis device derived pH and pCO2 and direct enzymatic method. Materials and methods: Arterial blood samples were taken from 90 patients hospitalized in the intensive care unit. Bicarbonate level was simultaneously measured in the ABL 800 blood gas analyzer with the method of mathematical calculation from the pH and pCO2 and in the Roche Diagnostics Cobas c501 with the enzymatic method. The results were compared. Results: Pearson correlation coefficient between the two measurements was r=0.944 showing a significant positive relationship. Also value of the ICC calculation which was 0.963 showed that there was a significant agreement between the two measurement methods (p=0.0001). None of the 90 values were not out of the agreement limits, as shown in Bland-Altman graphic. Conclusion: The present study showed that bicarbonate measurements with the blood gas analyzers which give quick results are reliable and acceptable when compared with the results of the direct enzymatic method. © TurkJBiochem.com.en_US
dc.identifier.endpage272en_US
dc.identifier.issn1303829X
dc.identifier.issue3en_US
dc.identifier.scopusqualityN/Aen_US
dc.identifier.startpage270en_US
dc.identifier.urihttps://hdl.handle.net/20.500.12684/198
dc.identifier.volume36en_US
dc.indekslendigikaynakScopusen_US
dc.language.isotren_US
dc.publisherTurkish Biochemistry Societyen_US
dc.relation.ispartofTurkish Journal of Biochemistryen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectAcid-base balance; Calculated bicarbonate; Enzymatic bicarbonate assayen_US
dc.titleCorrelation of bicarbonate values measured with direct enzymatic method and blood gas analysis devicesen_US
dc.title.alternativeKan gazı analiz cihazı ve direkt enzim atik ölçüm metodu ile elde edilen bikarbonat değerlerinin korelasyonuen_US
dc.typeArticleen_US