Volatile organic compound concentrations under two different ventilation structures and their health risks in the adhesive tape manufacturing workplace

dc.authoriddumanoglu, yetkin/0000-0003-3381-4425en_US
dc.authoridAYVAZ, Coşkun/0000-0003-0052-0842en_US
dc.authorid, Fazilet Ozkaya Altin/0009-0001-0864-4228en_US
dc.authoridUzun, Burcu/0000-0002-0228-5674en_US
dc.authorscopusid7005892165en_US
dc.authorscopusid58525375000en_US
dc.authorscopusid57207952032en_US
dc.authorscopusid27367746800en_US
dc.authorscopusid6701394869en_US
dc.authorscopusid57207952909en_US
dc.authorscopusid57207949757en_US
dc.authorwosiddumanoglu, yetkin/A-6293-2016en_US
dc.authorwosidAYVAZ, Coşkun/D-6587-2019en_US
dc.authorwosidUzun, Burcu/JGD-5033-2023en_US
dc.contributor.authorSahin, Ulku Alver
dc.contributor.authorOgur, Nurgul Elif
dc.contributor.authorAyvaz, Coskun
dc.contributor.authorDumanoglu, Yetkin
dc.contributor.authorOnat, Burcu
dc.contributor.authorUzun, Burcu
dc.contributor.authorOzkaya, Fazilet
dc.date.accessioned2024-08-23T16:07:04Z
dc.date.available2024-08-23T16:07:04Z
dc.date.issued2023en_US
dc.departmentDüzce Üniversitesien_US
dc.description.abstractExposure to the high volatile organic compounds (VOCs) concentration in the workplaces where solvents are used is an essential point for worker's health. However, the VOCs in the indoor air of an adhesive tape production facilities that use large amounts of solvents and the health risk of the toxic compounds have not been sufficiently investigated to this date. VOC samples were collected in the morning and afternoon times of day in the indoor air of workplaces of an adhesive tape production facility at 9 different points under two different central ventilation conditions. Carbon dioxide, humidity, temperature, flow rate, and pressure values were measured continuously throughout the work time with an average recording period of 1 min. The total VOC value had a wide range from 0.1 to 138 mg/m(3). BTEX (benzene, toluene, ethylbenzene, xylenes) contribution to total VOC accounted for between 40 and 60% and the toluene, methylepentane, and trichloroethane concentrations among the sampling points and campaigns dominated the total VOCs. The total hazard quotient (HQ) values for each measurement campaigns were higher than the acceptable limit of 1.0, while the lifetime cancer risk (LCR) values for benzene and carbon tetrachloride were lower than the acceptable limit of 1.0x10(-6). This observational study suggests that the effective and efficient operation of the workplace ventilation systems and the feasibility of the designed ventilation systems are essential on the accumulation of toxic compounds in the air and must be well evaluated.en_US
dc.description.sponsorshipResearch Fund of the Istanbul University-Cerrahpasa [FYL-2017-24775, FYL-2019-33331, FYL-2019-33302]en_US
dc.description.sponsorshipThis research supported by the Research Fund of the Istanbul University-Cerrahpasa (grant numbers FYL-2017-24775, FYL-2019-33331, FYL-2019-33302).en_US
dc.identifier.doi10.1007/s11869-023-01399-w
dc.identifier.endpage2191en_US
dc.identifier.issn1873-9318
dc.identifier.issn1873-9326
dc.identifier.issue11en_US
dc.identifier.scopus2-s2.0-85166925761en_US
dc.identifier.scopusqualityQ2en_US
dc.identifier.startpage2177en_US
dc.identifier.urihttps://doi.org/10.1007/s11869-023-01399-w
dc.identifier.urihttps://hdl.handle.net/20.500.12684/14472
dc.identifier.volume16en_US
dc.identifier.wosWOS:001042792200001en_US
dc.identifier.wosqualityQ3en_US
dc.indekslendigikaynakWeb of Scienceen_US
dc.indekslendigikaynakScopusen_US
dc.language.isoenen_US
dc.publisherSpringeren_US
dc.relation.ispartofAir Quality Atmosphere and Healthen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectVolatile organic compoundsen_US
dc.subjectOccupation healthen_US
dc.subjectSolvent industryen_US
dc.subjectTolueneen_US
dc.subjectVentilationen_US
dc.subjectCompounds Vocsen_US
dc.subjectOccupational-Exposureen_US
dc.subjectSeasonal-Variationsen_US
dc.subjectRespiratory Healthen_US
dc.subjectSource Profilesen_US
dc.subjectIndooren_US
dc.subjectAiren_US
dc.subjectQualityen_US
dc.subjectFineen_US
dc.subjectPollutantsen_US
dc.titleVolatile organic compound concentrations under two different ventilation structures and their health risks in the adhesive tape manufacturing workplaceen_US
dc.typeArticleen_US

Dosyalar