Thermal modelling and analysis of high-voltage insulated power cables under transient loads
dc.contributor.author | Aras, Faruk | |
dc.contributor.author | Biçen, Yunus | |
dc.date.accessioned | 2020-04-30T23:34:40Z | |
dc.date.available | 2020-04-30T23:34:40Z | |
dc.date.issued | 2013 | |
dc.department | DÜ, Düzce Meslek Yüksekokulu, Elektronik ve Otomasyon Bölümü | en_US |
dc.description | Faruk ARAS, Dr./0000-0001-5513-9139; bicen, yunus/0000-0001-8712-2286 | en_US |
dc.description | WOS: 000321259400014 | en_US |
dc.description.abstract | This article presents a simple thermal model for transient analysis of high-voltage underground power cables based on proper ladder diagram at MATLAB-Simulink software under various operating conditions for engineering students. Available commercial programs created with commercial worries are not suitable for students during the learning process, which involve different applications on power cable analysis. The model gives an opportunity for students to solve the often-faced transient problems in utilities. The transient model of the underground power cable system using the analytic procedures based on IEC60853 standards is presented with an example solution of the 154kV power cable in service in Turkish transmission system in this article. (c) 2010 Wiley Periodicals, Inc. Comput Appl Eng Educ 21: 516-529, 2013 | en_US |
dc.identifier.doi | 10.1002/cae.20497 | en_US |
dc.identifier.endpage | 529 | en_US |
dc.identifier.issn | 1061-3773 | |
dc.identifier.issn | 1099-0542 | |
dc.identifier.issue | 3 | en_US |
dc.identifier.scopusquality | Q1 | en_US |
dc.identifier.startpage | 516 | en_US |
dc.identifier.uri | https://doi.org/10.1002/cae.20497 | |
dc.identifier.uri | https://hdl.handle.net/20.500.12684/5204 | |
dc.identifier.volume | 21 | en_US |
dc.identifier.wos | WOS:000321259400014 | en_US |
dc.identifier.wosquality | Q4 | en_US |
dc.indekslendigikaynak | Web of Science | en_US |
dc.indekslendigikaynak | Scopus | en_US |
dc.language.iso | en | en_US |
dc.publisher | Wiley | en_US |
dc.relation.ispartof | Computer Applications In Engineering Education | en_US |
dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | en_US |
dc.rights | info:eu-repo/semantics/closedAccess | en_US |
dc.subject | power cable | en_US |
dc.subject | thermal model | en_US |
dc.subject | transient analysis | en_US |
dc.subject | Matlab tools | en_US |
dc.subject | computer simulation | en_US |
dc.title | Thermal modelling and analysis of high-voltage insulated power cables under transient loads | en_US |
dc.type | Article | en_US |
Dosyalar
Orijinal paket
1 - 1 / 1
Küçük Resim Yok
- İsim:
- 5204.pdf
- Boyut:
- 833.87 KB
- Biçim:
- Adobe Portable Document Format
- Açıklama:
- Tam Metin / Full Text