Analysis of Reduced Order Model Based on Doubly-Fed Induction Generators during Different Fault Times
dc.contributor.author | Döşoğlu, Mehmet Kenan | |
dc.contributor.author | Arsoy, Aysen Basa | |
dc.date.accessioned | 2020-04-30T22:39:21Z | |
dc.date.available | 2020-04-30T22:39:21Z | |
dc.date.issued | 2013 | |
dc.department | DÜ, Teknoloji Fakültesi, Elektrik-Elektronik Mühendisliği Bölümü | en_US |
dc.description | 8th International Conference on Electrical and Electronics Engineering (ELECO) -- NOV 28-30, 2013 -- Bursa, TURKEY | en_US |
dc.description | ARSOY, AYS EN BASA/0000-0002-5729-0366 | en_US |
dc.description | WOS: 000333752200045 | en_US |
dc.description.abstract | In this study, three phase fault analysis of wind turbines consist of Doubly-Fed Induction Generators (DFIGs) has been examined. The dynamic analysis of DFIG has been conducted by Reduced Order Model (ROM). Three Phase fault has been made in 34.5 kV bus, happended in three bus power systems. The three phase fault time has been choosen as 0.02 second, 0.05 second and 0.1 seconds. 154 kV bus voltage, 34.5 kV bus voltage, DFIG output voltage, DFIG angular speed, DFIG electrical torque and DFIG d-q axes stator and rotor current variations of system in different fault times has been examined. According to the results, it has been seen that three phase fault is especially effective upon 34.5 kV bus voltage and DFIG output voltage in different fault time's analysis. | en_US |
dc.description.sponsorship | Chamber Elect Engineers Bursa Branch, Istanbul Techn Univ, Fac Elect & Elect Engn, Uludag Univ, Dept Elect & Elect Engn, IEEE, Reg 8, IEEE Turkey Sect, CAS Chapter, Sci & Technol Res Council Turkey | en_US |
dc.identifier.endpage | 219 | en_US |
dc.identifier.isbn | 978-605-01-0504-9 | |
dc.identifier.startpage | 215 | en_US |
dc.identifier.uri | https://hdl.handle.net/20.500.12684/2692 | |
dc.identifier.wosquality | N/A | en_US |
dc.indekslendigikaynak | Web of Science | en_US |
dc.indekslendigikaynak | Scopus | en_US |
dc.language.iso | en | en_US |
dc.publisher | Ieee | en_US |
dc.relation.ispartof | 2013 8Th International Conference On Electrical And Electronics Engineering (Eleco) | en_US |
dc.relation.publicationcategory | Konferans Öğesi - Uluslararası - Kurum Öğretim Elemanı | en_US |
dc.rights | info:eu-repo/semantics/closedAccess | en_US |
dc.title | Analysis of Reduced Order Model Based on Doubly-Fed Induction Generators during Different Fault Times | en_US |
dc.type | Conference Object | en_US |
Dosyalar
Orijinal paket
1 - 1 / 1
Küçük Resim Yok
- İsim:
- 2692.pdf
- Boyut:
- 144.67 KB
- Biçim:
- Adobe Portable Document Format
- Açıklama:
- Tam Metin / Full Text