Genetic Algorithm Application for Hydrometer Tests

dc.contributor.authorÖzgan, Ercan
dc.contributor.authorÖztürk, Ali
dc.date.accessioned2020-05-01T12:10:11Z
dc.date.available2020-05-01T12:10:11Z
dc.date.issued2009
dc.departmentDÜ, Teknik Eğitim Fakültesi, Yapı Eğitimi Bölümüen_US
dc.descriptionWOS: 000271301600038en_US
dc.description.abstractIn this study, the results of the hydrometer tests were analyzed with statistical method and optimized by using genetic algorithms. For hydrometer tests; 0, 10, 20, 30, 40, 50 and 60 g sodium-hexametaphosphate was respectively added into the prepared suspension. The specific gravity, pH and the conductivity were measured for each solution. As pointed out in the Turkish Standard (TS 1900), the soil' grain diameter in the suspension prepared with 40 g sodium hexametaphosphate was taken into consideration as reference. As a result. it was determined that the soil' average grain diameter in suspension added 0 g sodium hexametaphosphate was bigger 4.515 times than the reference grain diameter. When respectively added 10 g sodium hexametaphosphate in the suspension, the soil average grain diameter bigger was 3.907 times than the reference grain diameter, when 20 g was added. It was 3.463 times bigger and in adding it was 30 g 2.119 times bigger. Besides, the hydrometer reading could only be done at 260 min when 50 g sodium hexametaphosphate was added in to the suspension. Moreover, the hydrometer couldn't be read in the suspension prepared with 60 g sodium hexametaphosphate. The obtained data were analyzed statistically by using SPSS programme and the experimental results were optimized by using genetic algorithms.en_US
dc.identifier.endpage6868en_US
dc.identifier.issn0970-7077
dc.identifier.issue9en_US
dc.identifier.scopusqualityQ4en_US
dc.identifier.startpage6857en_US
dc.identifier.urihttps://hdl.handle.net/20.500.12684/6062
dc.identifier.volume21en_US
dc.identifier.wosWOS:000271301600038en_US
dc.identifier.wosqualityQ4en_US
dc.indekslendigikaynakWeb of Scienceen_US
dc.indekslendigikaynakScopusen_US
dc.language.isoenen_US
dc.publisherAsian Journal Of Chemistryen_US
dc.relation.ispartofAsian Journal Of Chemistryen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectHydrometer testen_US
dc.subjectSodium hexametaphosphateen_US
dc.subjectOptimizationen_US
dc.subjectGenetic algorithmsen_US
dc.titleGenetic Algorithm Application for Hydrometer Testsen_US
dc.typeArticleen_US