Rotor Electrical Fault Detection in DFIGs Using Wide-Band Controller Signals

Yükleniyor...
Küçük Resim

Tarih

2021

Dergi Başlığı

Dergi ISSN

Cilt Başlığı

Yayıncı

Ieee-Inst Electrical Electronics Engineers Inc

Erişim Hakkı

info:eu-repo/semantics/openAccess

Özet

This paper presents a novel study of the wide-band spectral signatures in the controller signals of doubly fed induction generators (DFIGs) for the identification of rotor electrical faults. The aim is to advance the understanding of diagnostic information obtainable from the readily available DFIG controller signals. Analytical equations defining the controller signals possible spectral contents are derived to enable characterization of spectral signatures and their correlation to operating conditions and rotor faults. The equations are verified in a DFIG harmonic model study and also validated by undertaking a range of experiments on a laboratory DFIG test-rig. It is shown that the calculated, simulated and experimental results are in good agreement with regards to representing fault induced signatures in the examined DFIG controller signals spectra. Furthermore, it is shown that wide-band rotor electrical fault related spectral signatures in the controller signals carry considerable diagnostic potential for recognition of rotor electrical faults.

Açıklama

Anahtar Kelimeler

Rotors, Doubly fed induction generators, Stators, Mathematical model, Fault detection, Harmonic analysis, Condition monitoring, doubly fed induction generator, harmonic machine model, rotor electrical fault, signature analysis, Simulink, wind turbine, Signature Analysis, Wind Turbines, Wound-Rotor, Diagnosis, Performance, Generators, Stability

Kaynak

Ieee Transactions On Sustainable Energy

WoS Q Değeri

Q1

Scopus Q Değeri

Q1

Cilt

12

Sayı

1