Thermodynamic analysis of PID controlled fluidised bed dryer with parabolic trough collector

dc.contributor.authorGürel, Ali Etem
dc.contributor.authorCeylan, İlhan
dc.contributor.authorYılmaz, Sezayi
dc.date.accessioned2020-04-30T23:34:41Z
dc.date.available2020-04-30T23:34:41Z
dc.date.issued2015
dc.departmentDÜ, Düzce Meslek Yüksekokulu, Elektrik ve Enerji Bölümüen_US
dc.descriptionGurel, Ali Etem/0000-0003-1430-8041en_US
dc.descriptionWOS: 000364808500004en_US
dc.description.abstractThe aim of the current study was to investigate how to use hot water obtained by parabolic trough collector (PTC) in an air handling unit. The system consisted of a PTC, a water depot, a pump, an air handling unit, a fan, and control equipments. The purpose of the system was to maintain the set value without using an additional heater in the air handling unit. During the process, +/- 0.36 degrees C accuracy was achieved in a 40 degrees C set temperature. Uncertainty analyses were made for the measured temperature value and they were obtained as +/- 0.44 degrees C. The energy and exergy efficiency were calculated for the system. The heating performance coefficient (HPC) was defined as the ratio of the obtained energy from the system to the compulsory energy supplied to the system. The HPC was calculated as 3 on average. Heat energy of the water in the depot was converted to heat energy of the air in the system with an average 52 % exergy efficiency.en_US
dc.description.sponsorshipKarabuk University Scientific Research Projects UnitKarabuk Universityen_US
dc.description.sponsorshipThe authors are grateful for the support of the Karabuk University Scientific Research Projects Unit.en_US
dc.identifier.doi10.1504/IJEX.2015.072057en_US
dc.identifier.endpage83en_US
dc.identifier.issn1742-8297
dc.identifier.issn1742-8300
dc.identifier.issue1en_US
dc.identifier.scopusqualityQ3en_US
dc.identifier.startpage68en_US
dc.identifier.urihttps://doi.org/10.1504/IJEX.2015.072057
dc.identifier.urihttps://hdl.handle.net/20.500.12684/5206
dc.identifier.volume18en_US
dc.identifier.wosWOS:000364808500004en_US
dc.identifier.wosqualityQ2en_US
dc.indekslendigikaynakWeb of Scienceen_US
dc.indekslendigikaynakScopusen_US
dc.language.isoenen_US
dc.publisherInderscience Enterprises Ltden_US
dc.relation.ispartofInternational Journal Of Exergyen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectdryingen_US
dc.subjectexergyen_US
dc.subjectenergyen_US
dc.subjectPTCen_US
dc.subjectparabolic trough collectoren_US
dc.titleThermodynamic analysis of PID controlled fluidised bed dryer with parabolic trough collectoren_US
dc.typeArticleen_US

Dosyalar

Orijinal paket
Listeleniyor 1 - 1 / 1
Küçük Resim Yok
İsim:
5206.pdf
Boyut:
1.58 MB
Biçim:
Adobe Portable Document Format
Açıklama:
Tam Metin / Full Text