Stress Distribution Comparisions of Fixed and Broken Fibula, a Finite Element Study

dc.contributor.authorÖzkan, Arif
dc.contributor.authorKişioğlu, Yasin
dc.date.accessioned2020-04-30T23:32:14Z
dc.date.available2020-04-30T23:32:14Z
dc.date.issued2014
dc.departmentDÜ, Mühendislik Fakültesi, Biyomedikal Mühendisliği Bölümüen_US
dc.descriptionOZKAN, Arif/0000-0002-1288-6166en_US
dc.descriptionWOS: 000339429200003en_US
dc.description.abstractThe purpose of this study was to compare load carrying capacity and stress distributions of broken fibula on lower extremity under the average body weight and moment using with three-dimensional finite element analysis (FEA). The finite element (FE) models were generated from patient's computed tomography (CT) data images. The loading and the relevant boundary conditions selected according to average human body conditions for obtaining the stress distribution on tibia surface. According the all FE analysis fibula is an effective role for load carrying capacity on distal side of tibia. These FEA results showed that the loading characteristics of the fibula should be taken into account in planning medical and surgical operations.en_US
dc.identifier.doi10.1166/jbt.2014.1189en_US
dc.identifier.endpage442en_US
dc.identifier.issn2157-9083
dc.identifier.issn2157-9091
dc.identifier.issue6en_US
dc.identifier.scopusqualityN/Aen_US
dc.identifier.startpage439en_US
dc.identifier.urihttps://doi.org/10.1166/jbt.2014.1189
dc.identifier.urihttps://hdl.handle.net/20.500.12684/4658
dc.identifier.volume4en_US
dc.identifier.wosWOS:000339429200003en_US
dc.identifier.wosqualityQ4en_US
dc.indekslendigikaynakWeb of Scienceen_US
dc.indekslendigikaynakScopusen_US
dc.language.isoenen_US
dc.publisherAmer Scientific Publishersen_US
dc.relation.ispartofJournal Of Biomaterials And Tissue Engineeringen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectStress Distributionen_US
dc.subjectFinite Element Analysisen_US
dc.subjectBio-Modelingen_US
dc.subjectComputerized Tomographyen_US
dc.subjectTibiaen_US
dc.subjectFibulaen_US
dc.titleStress Distribution Comparisions of Fixed and Broken Fibula, a Finite Element Studyen_US
dc.typeArticleen_US