DFIG current and controller signals' angular shaft misalignment signature - an experimental case study

Yükleniyor...
Küçük Resim

Tarih

2020

Dergi Başlığı

Dergi ISSN

Cilt Başlığı

Yayıncı

Ieee

Erişim Hakkı

info:eu-repo/semantics/closedAccess

Özet

with the continuous increase in wind turbine generator size the monitoring and diagnosis of drive train shaft misalignment is of growing importance, as this condition contributes to as much as 30% of turbine's downtime. Machine current signature analysis has been widely investigated in conventional machinery as a non-invasive diagnostic tool for shaft misalignment, via spectrum analysis of the stator current signal. This paper reports a practical case study of misalignment fault signature manifestation in the doubly-fed induction generator (DFIG) controller signals spectra, with a view to assessing the feasibility of low cost and non-invasive controller signal analysis based misalignment diagnosis. The study employs a laboratory test rig to undertake a series of tests to analyze the sensitivity of controller signals to a specific angular misalignment condition, and hence evaluate and characterize the manifestation of its spectral signatures.

Açıklama

International Conference on Electrical Machines (ICEM) -- AUG 23-26, 2020 -- ELECTR NETWORK

Anahtar Kelimeler

Condition monitoring, DFIG shaft misalignment, angular misalignment, motor current signature analysis (MCSA), control signals signature analysis