Evaluation of tear function tests and corneal thickness in patients with meibomian gland dysfunction
dc.authorid | ||
dc.contributor.author | Teberik, Kuddusi | |
dc.contributor.author | İritaş, İlter | |
dc.date.accessioned | 2021-12-01T18:23:41Z | |
dc.date.available | 2021-12-01T18:23:41Z | |
dc.date.issued | 2020 | |
dc.department | [Belirlenecek] | en_US |
dc.description.abstract | Objectives: To investigate whether central corneal thickness (CCT) and tear function test differ from healthycontrols in the ones suffering meibomian gland dysfunction (MGD).Methods: This prospective study was carried out with 99 individuals in total (50 patients MGD, 49 healthyindividuals). Schirmer-1, tear break-up time (TBUT), the Ocular Surface Disease Index (OSDI) questionnaireand CCT measurmentwas administered to all patients.Results: The average Schirmer 1 measurements were 16.6 ± 3.3 mm for right eyes, 16.4 ± 3.6 mm for lefteyes in the MGD group and 17.1 ± 3.7 mm for right eyes, 17.0 ± 4.4 mm for left eyes in the control group. Themean TBUT values were 10.1 ± 3.6 seconds for right eyes, 10.2 ± 3.4 seconds for left eyes in the MGD groupand 14.7±3.7 seconds for right eyes, 15.8 ± 4.1 seconds for left eyes in the control group (p = 0.001). Themean OSDI score values were 40.3 ± 23.7 in the MGD group and 19.4 ± 8.7 in the control group (p = 0.001).The average CCT in the MGD group was 539.4 ± 30.0 µm and 539.7 ± 33.0 µm (right and left, respectively).The average CCT in the control group was 551.6 ± 32.8 µm and 550.7 ± 32.2 µm (right and left, respectively).The mean CCT measurements in the MGD group were not statistically significant compared to the healthycontrol group (p = 0.059, and p = 0.097, right and left, respectively).Conclusions: The Schirmer test and CCT measurements are not significantly different in patients with MGDcompared to healthy control subjects | en_US |
dc.identifier.doi | 10.18621/eurj.558779 | |
dc.identifier.endpage | 614 | en_US |
dc.identifier.issn | 2149-3189 | |
dc.identifier.issn | 2149-3189 | |
dc.identifier.issue | 6 | en_US |
dc.identifier.startpage | 609 | en_US |
dc.identifier.uri | https://doi.org/10.18621/eurj.558779 | |
dc.identifier.uri | https://app.trdizin.gov.tr/makale/TkRZeE5ERTFOUT09 | |
dc.identifier.uri | https://hdl.handle.net/20.500.12684/9755 | |
dc.identifier.volume | 6 | en_US |
dc.indekslendigikaynak | TR-Dizin | en_US |
dc.language.iso | en | en_US |
dc.relation.ispartof | The European Research Journal | en_US |
dc.relation.publicationcategory | Makale - Ulusal Hakemli Dergi - Kurum Öğretim Elemanı | en_US |
dc.rights | info:eu-repo/semantics/openAccess | en_US |
dc.subject | [No Keywords] | en_US |
dc.title | Evaluation of tear function tests and corneal thickness in patients with meibomian gland dysfunction | en_US |
dc.type | Article | en_US |
Dosyalar
Orijinal paket
1 - 1 / 1
Yükleniyor...
- İsim:
- 9755.pdf
- Boyut:
- 398.76 KB
- Biçim:
- Adobe Portable Document Format
- Açıklama:
- Tam Metin / Full Text