Arşiv logosu
  • Türkçe
  • English
  • Giriş
    Yeni kullanıcı mısınız? Kayıt için tıklayın. Şifrenizi mi unuttunuz?
Arşiv logosu
  • Koleksiyonlar
  • Sistem İçeriği
  • Analiz
  • Talep/Soru
  • Türkçe
  • English
  • Giriş
    Yeni kullanıcı mısınız? Kayıt için tıklayın. Şifrenizi mi unuttunuz?
  1. Ana Sayfa
  2. Yazara Göre Listele

Yazar "Köse, Mehmet" seçeneğine göre listele

Listeleniyor 1 - 1 / 1
Sayfa Başına Sonuç
Sıralama seçenekleri
  • Yükleniyor...
    Küçük Resim
    Öğe
    Detection of the glenoid bare spot by non-arthrographic MR imaging, conventional MR arthrography, and 3D high-resolution T1-weighted VIBE MR arthrography: comparison with CT arthrography
    (Springer, 2023) Özel, Mehmet Ali; Oğul, Hayri; Köksal, Ali; Köse, Mehmet; Tuncer, Kutsi; Eren, Suat; Kantarcı, Mecit
    ObjectivesTo determine the diagnostic accuracy of non-arthrographic MR imaging, conventional MR arthrography, and 3D T1-weighted volumetric interpolated breath-hold examination (VIBE) MR arthrography sequences as compared with a CT arthrography in the diagnosis of glenoid bare spot.MethodsA retrospective study of 216 patients who underwent non-arthrographic MR imaging, conventional MR arthrography, VIBE MRI arthrography, and CT arthrogram between January 2011 and March 2022 was conducted. The diagnostic accuracy of non-arthrographic MR imaging, direct MR arthrography, and VIBE MRI arthrography in the detection of glenoid bare spot was compared with that of CT arthrography. All studies were reviewed by 2 MSK radiologists. Interobserver agreement for MR imaging and MR arthrographic findings was calculated.ResultsSixteen of 216 patients were excluded. Twenty-three of 200 shoulders had glenoid bare spot on CT arthrographic images. The glenoid bare spot was detected in 11 (47.8%) and 7 (30.4%) patients on conventional non-arthrographic MR images and in 18 (78.3%) and 16 (69.6%) patients on conventional MR arthrograms by observers 1 and 2, respectively. Both observers separately described the bare spot in 22 of 23 patients (95.7%) on 3D volumetric MR arthrograms. Interobserver variabilities were fair agreement for conventional non-arthrographic MR imaging (kappa = 0.35, p < 0.05), moderate agreement for conventional MR arthrogram (kappa = 0.50, p < 0.05), and near-perfect agreement for 3D volumetric MR arthrogram reading (kappa = 0.87, p < 0.05).ConclusionsA 3D high-resolution T1-weighted VIBE MR arthrography sequence may yield diagnostic performance that is comparable with that of CT arthrography in the diagnosis of glenoid bare spot.

| Düzce Üniversitesi | Kütüphane | Açık Erişim Politikası | Rehber | OAI-PMH |

Bu site Creative Commons Alıntı-Gayri Ticari-Türetilemez 4.0 Uluslararası Lisansı ile korunmaktadır.


Düzce Üniversitesi, Kütüphane ve Dokümantasyon Daire Başkanlığı, Düzce, TÜRKİYE
İçerikte herhangi bir hata görürseniz lütfen bize bildirin

DSpace 7.6.1, Powered by İdeal DSpace

DSpace yazılımı telif hakkı © 2002-2025 LYRASIS

  • Çerez Ayarları
  • Gizlilik Politikası
  • Son Kullanıcı Sözleşmesi
  • Geri Bildirim