Arşiv logosu
  • Türkçe
  • English
  • Giriş
    Yeni kullanıcı mısınız? Kayıt için tıklayın. Şifrenizi mi unuttunuz?
Arşiv logosu
  • Koleksiyonlar
  • Sistem İçeriği
  • Analiz
  • Talep/Soru
  • Türkçe
  • English
  • Giriş
    Yeni kullanıcı mısınız? Kayıt için tıklayın. Şifrenizi mi unuttunuz?
  1. Ana Sayfa
  2. Yazara Göre Listele

Yazar "Dumanoğlu, Yetkin" seçeneğine göre listele

Listeleniyor 1 - 1 / 1
Sayfa Başına Sonuç
Sıralama seçenekleri
  • Yükleniyor...
    Küçük Resim
    Öğe
    Determination of the personal, indoor and outdoor exposure levels of inorganic gaseous pollutants in different microenvironments in an industrial city
    (Springer, 2015) Bozkurt, Zehra; Doğan, Güray; Arslanbaş, Demet; Pekey, Beyhan; Pekey, Hakan; Dumanoğlu, Yetkin; Tuncel, Gürdal
    We measured SO2, NO2 and O-3 concentrations during the summer and winter in Kocaeli, Turkey. The sampling was carried out indoors and outdoors at homes, schools and offices. Personal samplers were also used to determine personal exposures to these pollutants. High NO2 and SO2 concentrations were observed in outdoor samples collected close to locations characterized by heavy urban traffic. Concentrations of O-3, on the other hand, were higher in rural areas around the city due to ozone distillation. For both sampling periods, the concentrations of outdoor SO2 and O-3 were higher than for indoor and personal samples; however, the NO2 concentrations were higher in indoor and personal samples, indicating that outdoor sources significantly contribute to indoor SO2 and O-3 levels and that indoor NO2 concentrations are primarily modulated by sources within buildings. Seasonal variations in pollutant concentrations showed statistically significant differences. Indoor and outdoor concentrations of NO2 and SO2 measured in the winter were higher than the levels measured in the summer; O-3 concentrations, on the other hand, exhibited the opposite trend. Active-to-passive concentration ratios for NO2, SO2 and O-3 were 0.99, 1.08 and 1.16, respectively; the corresponding outdoor ratios were 0.95, 0.99 and 1.00.

| Düzce Üniversitesi | Kütüphane | Açık Erişim Politikası | Rehber | OAI-PMH |

Bu site Creative Commons Alıntı-Gayri Ticari-Türetilemez 4.0 Uluslararası Lisansı ile korunmaktadır.


Düzce Üniversitesi, Kütüphane ve Dokümantasyon Daire Başkanlığı, Düzce, TÜRKİYE
İçerikte herhangi bir hata görürseniz lütfen bize bildirin

DSpace 7.6.1, Powered by İdeal DSpace

DSpace yazılımı telif hakkı © 2002-2025 LYRASIS

  • Çerez Ayarları
  • Gizlilik Politikası
  • Son Kullanıcı Sözleşmesi
  • Geri Bildirim