Arşiv logosu
  • Türkçe
  • English
  • Giriş
    Yeni kullanıcı mısınız? Kayıt için tıklayın. Şifrenizi mi unuttunuz?
Arşiv logosu
  • Koleksiyonlar
  • Sistem İçeriği
  • Analiz
  • Talep/Soru
  • Türkçe
  • English
  • Giriş
    Yeni kullanıcı mısınız? Kayıt için tıklayın. Şifrenizi mi unuttunuz?
  1. Ana Sayfa
  2. Yazara Göre Listele

Yazar "Bodur, Onur Can" seçeneğine göre listele

Listeleniyor 1 - 1 / 1
Sayfa Başına Sonuç
Sıralama seçenekleri
  • Küçük Resim Yok
    Öğe
    An in-vitro assessment of bisphenol a release from thermoplastic orthodontic appliances exposed to various beverages
    (Bmc, 2025) Avan, Basak Arslan; Bodur, Onur Can; Yildirim, Ertan; Osanmaz, Akin; Tuncer, Cumhur; Tuncer, Burcu Balos
    BackgroundThermoplastic orthodontic appliances have been used as retention devices for years and gaining popularity as aligners, alternative to fixed orthodontic mechanics. This study aims to assess Bisphenol-A (BPA) release from thermoplastic orthodontic appliances exposed to different beverages.MethodsThe appliances in this study were enrolled from aligners of Invisalign, ClearCorrect, and thermoplastic retention device, Essix ACE. Five different beverages (pure water, whole milk, coke, orange juice, filtered coffee) were determined and 5 glass tubes containing 10 ml of each beverage formed experiment groups. Appliance samples from each brand (with 0.50 +/- 0.0082 g weight) were inserted in glass tubes and left in room temperature for 1 h. Later, samples were removed and Flow Injection Liquid Chromatography/Mass-Mass Spectrometry (FIA-LC/MS-MS) analysis was performed to evaluate BPA release. Five glass tubes for each beverage group, which did not contain any appliance, were also analyzed with the same technique to detect the possible pre-existing BPA levels in the liquids.ResultsFIA-LC/MS-MS analysis showed no measurable amount of BPA in pure water and any beverage group. BPA was also not detected in samples without appliances.ConclusionBPA release was not detected from thermoplastic orthodontic appliances after 1 h of incubation in beverages. Within the limitations, different types of beverages were not found to affect BPA release from thermoplastic orthodontic materials. From a clinical perspective, further in-vivo studies will be useful with larger samples and longer term investigations.

| Düzce Üniversitesi | Kütüphane | Açık Erişim Politikası | Rehber | OAI-PMH |

Bu site Creative Commons Alıntı-Gayri Ticari-Türetilemez 4.0 Uluslararası Lisansı ile korunmaktadır.


Düzce Üniversitesi, Kütüphane ve Dokümantasyon Daire Başkanlığı, Düzce, TÜRKİYE
İçerikte herhangi bir hata görürseniz lütfen bize bildirin

DSpace 7.6.1, Powered by İdeal DSpace

DSpace yazılımı telif hakkı © 2002-2025 LYRASIS

  • Çerez Ayarları
  • Gizlilik Politikası
  • Son Kullanıcı Sözleşmesi
  • Geri Bildirim