Dursun, MustafaBoz, Ali Fuat2020-04-302020-04-3020151330-36511848-6339https://doi.org/10.17559/TV-20140912141639https://hdl.handle.net/20.500.12684/4774Boz, Ali Fuat/0000-0001-6575-7678; Dursun, Mustafa/0000-0001-9952-9358WOS: 000359365100017This paper presents the use of proportional integral (PI), proportional integral derivative (PID) and fuzzy logic (FL) speed controller techniques in the permanent magnet synchronous motor (PMSM) drive. PI and PID controllers require precise linear mathematical model of the system. On the other hand, FL needs linguistic description of the system. The dynamic response of PMSM with the controllers was studied under different load disturbances. The effectiveness of the fuzzy logic controller was compared with the conventional PI and PID controllers. The FL controller responded better than conventional techniques under transient load conditions and also achieved faster settling response.en10.17559/TV-20140912141639info:eu-repo/semantics/openAccessfuzzy logic controllerpermanent magnet synchronous motor (PMSM)PI controllertransient loadsTHE ANALYSIS OF DIFFERENT TECHNIQUES FOR SPEED CONTROL OF PERMANENT MAGNET SYNCHRONOUS MOTORArticle224947952WOS:000359365100017Q3Q4