Apay, Ahmet CelalÖzgan, ErcanTurgay, TahsinAkyol, Kevser2020-04-302020-04-3020160950-06181879-0526https://doi.org/10.1016/j.conbuildmat.2016.03.110https://hdl.handle.net/20.500.12684/3423TURGAY, Tahsin/0000-0003-0304-1097WOS: 000375817400072In this study, structural waterproofing products, structural water insulation applications and effects of waterproofing admixtures on the concrete were experimentally investigated. Different dosages in the concrete mixture (0%, 0.5%, 1.0%, 1.5% and 2.0%) were used to determine the effect of the chemical additive on the permeability of the concrete and the compressive strength the chemical additives. Maximum particle diameter of the aggregate used in the concrete mixture was selected 32 mm accordance to the Turkish Standard 802 "Design of concrete mixes" (TS 802) [1]. The selected aggregate granulometry of concrete mixture is located in B32 section of this granulometry curve and by using PC 42.5 cement, 320 kg/m(3) dosage concretes were produced in laboratory by adding four different kinds of aggregates. The compressive strength and permeability of the hardened concrete samples were measured after 14 days. The measured results showed that while maximum compressive strength were measured as 36.1 N/mm(2) on the concrete samples prepared with 2% chemical additive the minimum water absorption were measured as 4% on the same samples. However, while minimum compressive strength were measured as 28.5 N/mm(2) on the concrete samples prepared with 0% (Reference samples) chemical additives the maximum water absorption were measured as 5.9% on the same samples. Statistical analyses were conducted to determine the relationship between experimental parameters on the compressive strength and water absorption of the hardened concrete samples. By using Adaptive Neural Fuzzy Inference System (ANFIS) prediction models were developed based on the experimental inputs to predict the compressive strength and water absorption of the hardened concrete samples. The results showed that both statistical and ANFIS methods' results have perfect match with experimental results. The prediction models can be used to predict the compressive strength and water absorption of concrete samples for known and unknown experimental inputs values. (C) 2016 Elsevier Ltd. All rights reserved.en10.1016/j.conbuildmat.2016.03.110info:eu-repo/semantics/closedAccessConcreteWaterproofingAbsorptionCompressive strengthModellingANFISMLRInvestigation and modelling the effects of water proofing and water repellent admixtures dosage on the permeability and compressive strengths of concreteArticle113698711WOS:000375817400072Q1Q1